4000326 Rev A Optical Switches 3-31
Configure Parameters Using LCI,
Continued
Parameter Description Values Default
Hysteresis
Amplitude
Hysteresis Amplitude: the value
(in dB relative to switching
threshold) above which the
input optical power must rise
for the switch to begin the
hysteresis timer before restoring
original switch position. Only
applies if Revert is True.
0.5 dB to 9.5 dB,
increments of 0.1 dB
0.5 dB
Revert
In Auto, allows switch to
revert to primary position
after optical power is
restored.
In Manual, switch will
remain in backup position
Manual
Auto
Auto
Primary
Optical
Input
Selects the primary optical
input.
Port 3
Port 4
Port 4
Set Switch
Position
Selects the Normal switch
position.
Cross
Bar
Bar