26
Figure 33 Connecting an Alarm Device to the Cisco AS5350XM Universal Gateway
Figure 34 Connecting an Alarm Device to the Cisco AS5400XM Universal Gateway
Step 4 Attach two cable ties to the chassis, and connect the wires to the cable ties.
Step 5 Attach the alarm wires to the alarm device. Table 4 describes the alarm pinouts.
Table 4 Alarm Pinouts
Pin
1
1. The pins are numbered from left to right (facing the back of
the chassis), starting with pin 1.
Description
1 Normally open
2Pole
3 Normally closed
35967
Alarm port
connector
To alarm device
Cable ties
#1
#2
#3
35145
Alarm port
connector
Cable ties
#1
#2
#3