1-60
Cisco 7200 VXR Installation and Configuration Guide
OL-5013-09
Chapter 1 Cisco 7200 VXR Product Overview
Functional Overview
Table 1-34 NPE-G2 Processor-Monitored Temperature Thresholds
NPE-G2
1
1. With an I/O controller installed.
Low Warning High Warning Shutdown
NPE inlet 111°F (44°C) 138°F (59°C) 176
o
F (80
o
C)
NPE outlet 120°F (49°C) 147°F (64°C) 183°F (84°C)
I/O controller inlet 105°F (41°C) 132°F (56°C) 168°F (76°C)
I/O controller outlet 107°F (42°C) 134°F (57°C) 170°F (77°C)
CPU Die 194°F (90°C) 221°F (105°C) 230°F (110°C)
Table 1-35 NPE-G1 Processor-Monitored Temperature Thresholds
NPE-G1
1
1. With an I/O controller installed.
Low Warning High Warning Shutdown
NPE inlet 111°F (44°C) 138°F (59°C) 176°F (80°C)
NPE outlet 120°F (49°C) 147°F (64°C) 183°F (84°C)
I/O controller inlet 105°F (41°C) 132°F (56°C) 168°F (76°C)
I/O controller outlet 107°F (42°C) 134°F (57°C) 170°F (77°C)
Table 1-36 Typical Processor-Monitored Temperature Thresholds
Parameter High Warning High Critical Shutdown
NPE-175, NPE-225, NPE-300,
NPE-400, NSE-1
Chassis inlet 104°F (40°C) 122°F (50°C) —
Chassis outlet 1 109°F (43°C) 127°F (53°C) 136°F (58°C)
Chassis outlet 2 109°F (43°C) 127°F (53°C) —
Chassis outlet 3 122°F (50°C) 140°F (60°C) 149°F (65°C)
NPE-100 or NPE-200
Chassis inlet 104°F (40°C) 122°F (50°C) —
Chassis outlet 1 109°F (43°C) 127°F (53°C) 136°F (58°C)
Chassis outlet 2 167°F (75°C) 167°F (75°C) —
Chassis outlet 3 122°F (50°C) 140°F (60°C) 149°F (65°C)
NPE-150
Chassis inlet 104°F (40°C) 122°F (50°C) —
Chassis outlet 1 109°F (43°C) 127°F (53°C) 136°F (58°C)
Chassis outlet 2 167°F (75°C) 167°F (75°C) —
Chassis outlet 3 131°F (55°C) 149°F (65°C) 158°F (70°C)