Data Sheet
© 2010 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 9 of 12
Feature Specification
Approvals and compliance Safety
●
UL60950 and CAN/CSA-C22.2 No. 60950. Information technology equipment
●
AS/NZS 60950
●
IEC/EN 60950 Information technology equipment
●
73/23/EEC
Electromagnetic Emissions Certification
●
AS/NZ 3548: 1995 (including AMD I + II) Class A
●
EN55022: 1998 Class A
●
CISPR 22: 1997
●
EN55022: 1994 (including AMD I + II)
●
47 CFR Part 15: 2000 (FCC) Class A
●
VCCI V-3/01.4 Class A
●
CNS-13438: 1997 Class A
●
GR1089: 1997 (including Rev. 1: 1999)
Immunity
●
EN300386: 2000-TNE EMC requirements; product family standard; high priority of service; central office
and noncentral office locations
●
EN50082-1: 1992/1997
●
EN50082-2: 1995-Generic Immunity Standard, Heavy Industrial
●
CISPR24: 1997
●
EN55024: 1998-Generic ITE immunity standard
●
EN61000-4-2: 1995 + AMD I + II ESD, Level 4/8 kV contact, 15 kV air
●
IEC-1000-4-3: 1995 + AMD 1-Radiated Immunity, 10 V/m
●
IEC-1000-4-4: 1995-Electrical Fast Transients, Level 4/4 kV/B
●
IEC-1000-4-5: 1995 + AMD 1-DC Surge-Class 3; AC Surge-Class 4
●
EN61000-4-6: 1996 + AMD 1-RF conducted immunity, 10V rms
●
EN61000-4-11: 1995-Voltage Dips and Sags
●
ETS300 132-2: 1996 + corrigendum, December 1996
●
GR1089:1997 (including Rev1: 1999)
Network Equipment Building Standards
●
The module meets the following Networking Equipment Building Standards (NEBS):
●
GR-1089-CORE
●
GR-63-CORE
●
European Telecommunication Standards Institute (ETSI)
●
ETSI 300 386-1 - Levels for equipment with a "high priority of service" that is installed in "locations other
than telecommunication centers"
●
ETSI 300 386-2:1997 - Levels for equipment with a "high priority of service" that is installed in "locations
other than telecommunication centers"
●
ETSI 300 132-2: December 1994 - Power supply interfaces at the input to telecommunications equipment
Sections 4.8 and 4.9
Environmental Storage temperature: -38 to 150°F (-40 to 70°C)
Operating temperature, nominal: 41 to 104°F (5 to 4 0°C)
Operating temperature, short-term: 23 to 131°F (-5 t o 55°C)
Storage relative humidity (RH): 5 to 95% RH
Operating humidity, nominal: 5 to 85% RH
Operating humidity, short-term: 5 to 90% RH
Operating altitude: -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Comentarios a estos manuales