2-18
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, Release 9.0
78-18394-01
Chapter 2 Alarm Troubleshooting
Trouble Notifications
Facility (port) alarms also follow a hierarchy; lower-ranking alarms are closed by higher-ranking alarms.
The facility alarm hierarchy used in the systems is shown in Table 2-10.
Near-end failures and far-end failures follow different hierarchies. Near-end failures stand according to
whether they are for the entire signal (LOS, loss of frame alignment [LOF]), facility (AIS-L), path
(AIS-P, etc.) or VT (AIS-V, etc.). The full hierarchy for near-end failures is shown in Table 2-11. This
table is taken from Telcordia GR-253-CORE.
Table 2-10 Facility Alarm Hierarchy
Priority Condition Type
Highest LOS
—LOF
—AIS-L
SF-L
—SD-L
—RFI-L
—TIM-S
—AIS-P
—LOP-P
SF-P
—SD-P
UNEQ-P
—TIM-P
Lowest PLM-P
Table 2-11 Near-End Alarm Hierarchy
Priority Condition Type
Highest LOS
—LOF
—AIS-L
—AIS-P
1
—LOP-P
2
UNEQ-P
—TIM-P
—PLM-P
—AIS-V
1
—LOP-V
2
UNEQ-V
Vista de pagina 147