1-42
Cisco 7100 Series VPN Router Installation and Configuration Guide
78-6341-03
Chapter 1 Overview
Functional Overview
Power Supply:
Power supply is standard power supply. Unit is on.
Temperature readings:
chassis core measured at 33C/91F
chassis inlet measured at 27C/80F
chassis outlet 1 measured at 30C/86F
chassis outlet 2 measured at 32C/89F
Voltage readings:
+2.5 V measured at +2.59 V
+3.3 V measured at +3.32 V
+5.15 V measured at +5.13 V
+12.3 V measured at +12.29 V
+12.3 V measured at +12.33 V
-12.5 V measured at -12.43 V
Envm stats saved 2 time(s) since reload
Fan Failures
When the system power is on, all four fans should be operational. The system continues to operate if a
fan fails; however, if the air temperature exceeds a defined threshold, the router displays warning
messages on the console terminal. (See the “Troubleshooting the Cooling Subsystem” section on
page 5-6.)
For complete descriptions and instructions of the environmental monitor commands, refer to the
Configuration Fundamentals Configuration Guide and Configuration Fundamentals Command
Reference publications, available online and on the Documentation CD.