© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 13 of 14
Description Cisco ASR 903 Router
Timing ports BITS simultaneous input and output (T1/E1) – RJ48 connector port
1PPS input – mini-coax connector port
1PPS output – mini-coax connector port
2.048/10MHz input – mini-coax connector port
2.048/10MHz output – mini-coax connector port
1PPS input or output and ToD input or output – RJ45 connector port
External USB flash
memory
Mass storage – USB 2.0 type A receptacle connector port
1. At one moment in time either the USB console port or the RS232 Serial Console/Aux port can be active. These ports cannot be active
concurrently.
Table 8. Power Specifications
Description Cisco ASR 903 Router
Power consumption Maximum input power 630W
AC input voltage and
frequency
Voltage range: 85VAC to 264 VAC, Nominal 115VAC/230VAC
Frequency Range: 47Hz to 63Hz, Nominal 60Hz/50Hz
DC input voltage Voltage range: -19.2VDC to -72VDC, Nominal -24VDC/ -48VDC
Table 9. Environmental Specifications
Description Cisco ASR 903 Router
Operating environment
and altitude
1
–40ºC to 65ºC operating temperature (DC operation)
–5ºC to 55ºC operating temperature (AC operation)
2
0ºC to 40ºC operating temperature (AC operation)
–60m to 1800m operating altitude (for full operating temperature range)
Up to 4000m operating altitude (at up to +40ºC temperature)
Relative humidity 5% to 95%, non-condensing
Acoustic noise
3
Acoustic noise peak operation maximum 55dBA sound pressure level, bystander position for rack mount products at
20ºC operation as measured by ISO 7779 NAIS noise measurement test standard
Acoustic noise peak operation compliant to the NEBS GR-63-Core Issue 3 sound power level of 78dB at 27ºC
operation as measured by the ANSI S12.10/ISO 7779 NAIS noise measurement test standard
Storage environment Temperature: –40 to +70ºC altitude: 15,000ft (4570m)
Seismic Zone 4
1. Optics used may limit the temperature range.
2. Not more than the following in a one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences.
3. The above are for normal (nonfailure) operation. When operating with a fan failure, the above may be exceeded.
Table 10. Safety and Compliance
Type Standards
Safety
UL 60950-1, 2nd edition
CAN/CSA C22.2 No. 60950-1-07 2nd edition
IEC 60950-1, 2nd edition
EN 60950-1, 2nd edition
AS/NZS 60950.1:2003
Electromagnetic
FCC CFR47 Part 15 Class A
Emissions Compliance
EN55022, class A
CISPR22, class A
ICES-003, class A
EN 300 386, class A
VCCI, class A
KN22, class A
EN61000-3-2 to EN61000-3-3