Item Specification
Environmental Storage temperature: -38 to 150ºF (-40 to 70ºC)
Operating temperature: nominal = 41 to 104ºF (5 to 40ºC)
Storage relative humidity: 5 to 95 percent relative humidity
Operating relative humidity: nominal 5 to 85 percent relative humidity
Operating altitude: -60 to 4000 m
RF Input/output impedance: 75 ohms
Maximum RF input power: +15 dBm (63.75 dBmV)
Switch type: electromechanical; absorptive for working path, nonabsorptive for protect path
Switch setting time per switch module: 20 ms maximum
Downstream frequency range: 54 to 860 MHz
Typical downstream insertion loss: +/-1.1 dB from CMTS to cable plant; +/- 2.1 dB from
protect path to cable plant; 5.5 dB from working path to output; 8.0 dB from protect path to
output
Downstream insertion loss flatness: +/- 1.1 dB from CMTS to cable plant; +/- 2.1 dB from
protect path to cable plant
Downstream output return loss: >15.0 dB at <450 MHz, >12.0 dB
at >= 450 MHz
Downstream input return loss: >15.0 dB
Downstream isolation: >60 dB from channel to channel in working mode; >52 dB from CMTS
to protect path when in protect mode
Upstream frequency range: 5 to 70 MHz
Typical upstream insertion loss: 4.1 dB from cable plant to CMTS; 5.2 dB from cable plant to
protect path
Upstream insertion loss flatness: +/- 0.4 dB from cable plant to CMTS, +/- 0.6 dB from cable
plant to protect path
Upstream input return loss: >16 dB
Upstream isolation: >60 dB from channel to channel in working mode; >60 dB from CMTS to
protect path when in protect mode
Protect mode: CMTS return loss >10 dB; cable plant return loss:
>10 dB
Regulatory compliance UL 1950, Third Edition (Safety of Information Technology Equipment, Including Electrical
Business Equipment)
CSA950
EN 60950 (Safety of Information Technology Equipment, Including Electrical Business
Equipment)
IEC950
ACA TS001 1997 Test Report and Statement of Compliance
AS/NZ3260