Catalyst 6000 Family Content Switching Module Installation and Configuration Note
78-11631-05
Chapter 1 Overview
RJ-45 Connector
The RJ-45 connector, which is covered by a removable plate, is used to connect a management station
device or a test device. This connector is used by field engineers to perform testing and to obtain dump
information.
Operation Mode
Clients and servers communicate through the CSM using Layer 2 and Layer 3 technology in a specific
VLAN configuration. (See Figure 1-2.) Clients connect to the client-side VLAN and servers connect to
the server-side VLAN. Servers and clients can exist on different subnets. Servers can also be located one
or more Layer 3 hops away and connect to the server-side VLAN through routers.
A client sends a request to one of the module’s VIP addresses. The CSM forwards this request to a server
that can respond to the request. The server then forwards the response to the CSM, and the CSM forwards
the response to the client.
When the client-side and server-side VLANs are on the same subnets, you can configure the CSM in
single subnet (bridge) mode. For more information, see the “Configuring the Single Subnet (Bridge)
Mode” section on page 4-2.
Table 1-2 Content Switching Module Status LED
Color Description
Off The module is waiting for the supervisor engine to provide power.
The module is not on line.
The module is not receiving power, which could be caused by the following:
Power is not available to the CSM.
Module temperature is over the limit
1
.
1. Enter the show environment temperature mod command to display the temperature of each of four sensors on the CSM.
Red The module is released from reset by the supervisor engine and is booting.
If the boot code fails to execute, the LED stays red after power up.
Orange The module is initializing hardware or communicating with the supervisor
engine.
A fault occurred during the initialization sequence.
The module has failed to download its Field Programmable Gate Arrays
(FPGAs) on power up, but continues with the remainder of the initialization
sequence and provides the module online status from the supervisor engine.
The module has not received module online status from the supervisor engine.
This problem could be caused by the supervisor engine detecting a failure in
an external loopback test that it issued to the CSM.
Green The module is operational; the supervisor engine has provided module online
status.
Green to orange The module is disabled through the supervisor engine CLI
2
using the set
module disable mod command.
2. CLI = command-line interface.