10-15
Cisco PIX Firewall and VPN
78-15033-01
Chapter 10 Using PIX Firewall Failover
Configuring LAN-Based Failover
Configuring the Secondary Unit
Follow these steps to configure the secondary unit for LAN-based failover. The only configuration
required for the secondary unit is for the failover interface and for LAN failover parameters. The
secondary unit requires these commands to initially communicate with the primary unit. After the
primary unit sends its configuration to the secondary unit, the only permanent difference between the
two configurations is the failover lan unit command, which identifies each unit as primary or secondary.
Although all other failover lan commands are the same on both units, these commands are not replicated
from the active unit to the standby unit and must be saved in Flash memory.
Note At any time during the procedure, you can enter the show failover command to see the failover status.
See the “Using the Show Failover Command” section for detailed information.
Step 7
primary(config)# failover lan
interface interface_name
Identifies the Ethernet interface for the failover link.
For example, enter:
primary(config)# failover lan interface faillink
Step 8
primary(config)# failover lan
key string
(Optional) Encrypts the failover communications over the
Ethernet link. If you do not enter this command, all failover
communications are sent in clear text.
Where string is a shared key.
Step 9
primary(config)# failover lan
enable
Enables the LAN-based failover link, instead of the default serial
failover cable link.
Step 10
primary(config)# failover
Enables failover.
Step 11
primary(config)# write memory
Saves the configuration to Flash memory.
Step/Command Description
Step/Command Description
Step 1
Configure the Ethernet interface you are
using for the failover link:
Use the same settings as the primary unit. See
“Configuring the Primary Unit” for details about the
following commands.
a.
secondary(config)# interface
hardware_id hardware_speed
Enables the interface.
For example:
secondary(config)# interface ethernet2 100full
b.
secondary(config)# nameif
hardware_id interface_name
securitylevel
Names the interface and sets the security level.
For example:
secondary(config)# nameif ethernet2 faillink
security90