Appendix D
CGI Commands
38
Wireless-N Internet Home Monitoring Camera
Appendix D
Parameter Value and description
md_name1
...
md_name4
Name of the motion detection area 1 ~ 4
(12 ASCII characters)
md_window1
...
md_window4
The coordinates of motion detection window N (relative to resolution 640x480)
X1, Y1, X2, Y2
md_threshold1
...
md_threshold4
The threshold of motion detection window N
(0 - 255)
Return:
HTTP/1.0 200 OK \r\n
content-type: text/plain\r\n
\r\n
OK\r\n
Notes: The first motion window is used for full screen.
Use “md_switch1” as the switch for “full screen or “sub-windows.
The md_window1 is always set to 640x480 resolution.
If “md_switch1=1”, then the Camera will detect the entire video screen. With this setting, the remaining
windows (sub-window 1~3) cannot be configured.
If “md_switch1=0”, then the Camera will detect the md_window2~4” areas.
Wireless Commands
Wireless status query
Method: GET
URL: http://<ip>/adm/wireless_status.cgi
Return: The Camera returns a Web page that contains the following messages:
HTTP/1.0 200 OK \r\n
content-type: text/plain\r\n
\r\n
signal_strength=100\r\n # Wireless signal, RSSI, Integer type, the value can be 1~100, 100 is the strongest.
\r\n