Pagina 1 - WWW.CISCO.COM

CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.1 NOVEMBER 2, 2012 WWW.CISCO.COMCisco UCS C22 M3High-Density Rack-Mou

Pagina 2 - CONTENTS

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server10CONFIGURING the SERVERSTEP 2 SELECT CPU(s)The standard CPU features are: Intel Xeon E5-2400 seri

Pagina 3 - OVERVIEW

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER11 For optimal performance, select DIMMs with the highest clock speed for a

Pagina 4 - DETAILED VIEWS

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server12CONFIGURING the SERVERSTEP 3 SELECT MEMORYThe standard memory features are: DIMMs— Clock speed:

Pagina 5 - Chassis Rear View

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER13Select DIMMsSelect the memory configuration. The available memory DIMMs are

Pagina 6

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server14CONFIGURING the SERVER Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on p

Pagina 7

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER15STEP 4 SELECT RAID CONFIGURATIONThe RAID controller choices are: Software

Pagina 8

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server16CONFIGURING the SERVERTable 6 Available Hardware RAID Options Product ID (PID) PID DescriptionR

Pagina 9 - STEP 1 VERIFY SERVER SKU

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER17Approved ConfigurationsSelect a software RAID option from Table 5 on page 1

Pagina 10 - STEP 2 SELECT CPU(s)

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server18CONFIGURING the SERVER— Note that only a single Cisco 1225 Virtual Interface Card (VIC) card is s

Pagina 11 - CONFIGURING the SERVER

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER19STEP 5 SELECT HARD DISK DRIVES (HDDs)The standard disk drive features are:

Pagina 12 - STEP 3 SELECT MEMORY

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server2CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 13

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server20CONFIGURING the SERVERApproved Configurations(1) Software RAID (LSI MegaSR) Select up to eight S

Pagina 14

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER21STEP 6 SELECT PCIe OPTION CARD(s)The standard PCIe card offerings are: Con

Pagina 15

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server22CONFIGURING the SERVERApproved Configurations(1) No RAID controller plug-in card If you did not

Pagina 16

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER23STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIESCopper twinax cables and SFP

Pagina 17

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server24CONFIGURING the SERVERChoose Optional SFP ModulesOptical Cisco SFP+ modules are listed in Table 1

Pagina 18

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER25Figure 5 Network Card Connections

Pagina 19 - ■ there are no drives, or

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server26CONFIGURING the SERVERSTEP 8 SELECT AC POWER CORD(s)Using Table 11, select the appropriate AC pow

Pagina 20

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER27SFS-250V-10A-AR Power Cord, SFS, 250V, 10A, ArgentinaCAB-9K10A-AU Power Cor

Pagina 21 - Notes . .

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server28CONFIGURING the SERVERCAB-9K10A-IT Power Cord, 250VAC 10A CEI 23-16/VII Plug, ItalyCAB-9K10A-SW P

Pagina 22

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER29STEP 9 ORDER POWER SUPPLYThe C22 M3 server accommodates one power supply. A

Pagina 23

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerOVERVIEW3 OVERVIEWThe Cisco® UCS C22 M3 Rack Server combines economics and a density-optimized feat

Pagina 24

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server30CONFIGURING the SERVERSTEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARMThe reversible cable

Pagina 25

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER31STEP 11 ORDER A TRUSTED PLATFORM MODULETrusted Platform Module (TPM) is a c

Pagina 26

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server32CONFIGURING the SERVERSTEP 12 ORDER OPTIONAL USB 2.0 DRIVESYou may order one or two optional USB

Pagina 27

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER33STEP 13 SELECT OPERATING SYSTEMSeveral operating systems are available from

Pagina 28

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server34CONFIGURING the SERVERVMWare ServerVMW-VS5-STD-1A VMware vSphere 5 Standard for 1 Processor, 1 Ye

Pagina 29 - STEP 9 ORDER POWER SUPPLY

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER35STEP 14 SELECT OPERATING SYSTEM MEDIA KITSelect the optional operating syst

Pagina 30

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server36CONFIGURING the SERVERSTEP 15 SELECT OPTIONAL VALUE-ADDED SOFTWAREYou can select from a variety o

Pagina 31

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER37STEP 16 SELECT SERVICE and SUPPORT LEVELA variety of service options are av

Pagina 32

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server38CONFIGURING the SERVERworld. As a part of this service, Cisco will assist in issues involving thi

Pagina 33

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER39Mission Critical Support ServiceThis service delivers personalized technica

Pagina 34

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server4DETAILED VIEWSDETAILED VIEWSChassis Front ViewFigure 2 shows the Cisco UCS C22 M3 High-Density SFF

Pagina 35

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server40CONFIGURING the SERVERabout Cisco Mission Critical Support Service, please visit Data Center Tech

Pagina 36

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerOPTIONAL STEP - ORDER RACK(s)41OPTIONAL STEP - ORDER RACK(s)The optional R42610 rack is available f

Pagina 37

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server42OPTIONAL STEP - ORDER PDUOPTIONAL STEP - ORDER PDUAn optional power distribution unit (PDU) is av

Pagina 38

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL43SUPPLEMENTAL MATERIALCHASSISAn internal view of the C22 M3 chassis with the

Pagina 39

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server44SUPPLEMENTAL MATERIALCPUs and DIMMsPhysical LayoutEach CPU has three DIMM channels: CPU1 has cha

Pagina 40 - Manager

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL45Figure 7 Physical Layout of CPU DIMM Channels and Banks285209A0A1B0B1C0C1D

Pagina 41 - OPTIONAL STEP - ORDER RACK(s)

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server46SUPPLEMENTAL MATERIALMemory Population RulesWhen considering the memory configuration of your ser

Pagina 42 - OPTIONAL STEP - ORDER PDU

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL47Recommended Memory PopulationThis section explains the recommended DIMM popu

Pagina 43 - SUPPLEMENTAL MATERIAL

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server48SUPPLEMENTAL MATERIALSupported DIMM PopulationsThe supported DIMM populations are listed in Table

Pagina 44 - CPUs and DIMMs

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL49Low-Voltage DIMM ConsiderationsThe C22 M3 server can be ordered with low-vol

Pagina 45

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerDETAILED VIEWS5Chassis Rear ViewFigure 3 shows the external features of the rear panel.Figure 3 C

Pagina 46 - Memory Population Rules

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server50SUPPLEMENTAL MATERIALRACKSThe Cisco R42610 rack (see Figure 8) is certified for Cisco UCS install

Pagina 47 - Recommended Memory Population

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL51Figure 8 Cisco R42610 RackFront view - door closed Front view - door open

Pagina 48 - Supported DIMM Populations

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server52SUPPLEMENTAL MATERIALPDUsCisco RP Series Power Distribution Units (PDUs) offer power distribution

Pagina 49

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL53Motherboard USB PortThe C22 M3 SFF motherboard has one general-purpose USB s

Pagina 50

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server54SUPPLEMENTAL MATERIALLED IndicatorsThe server contains LED indicators on the front and rear panel

Pagina 51 - Figure 8 Cisco R42610 Rack

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL55System Status Off UndefinedOn (green) Server is in normal operating conditio

Pagina 52

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server56SUPPLEMENTAL MATERIALRear PanelFigure 12 shows the rear panel LEDs.Figure 12 Front Panel LEDsBl

Pagina 53 - Motherboard USB Port

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerSUPPLEMENTAL MATERIAL57See Table 28 for the functions of the rear panel LEDs.Table 28 Rear Panel L

Pagina 54 - LED Indicators

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server58TECHNICAL SPECIFICATIONSTECHNICAL SPECIFICATIONSDimensions and WeightPower SpecificationsThe gene

Pagina 55

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerTECHNICAL SPECIFICATIONS59The general power specifications for the C22 M3 SFF server 650 W power su

Pagina 56 - Rear Panel

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server6BASE SERVER STANDARD CAPABILITIES and FEATURESBASE SERVER STANDARD CAPABILITIES and FEATURESTab le

Pagina 57

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server60TECHNICAL SPECIFICATIONSTemperature nonoperating –40 to 149°F (–40 to 65°C)Humidity (RH) nonopera

Pagina 58 - TECHNICAL SPECIFICATIONS

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerTECHNICAL SPECIFICATIONS61Compliance RequirementsThe regulatory compliance requirements for C-Serie

Pagina 59 - Environmental Specifications

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server62TECHNICAL SPECIFICATIONS

Pagina 60

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerBASE SERVER STANDARD CAPABILITIES and FEATURES7Video The Emulex Pilot 3 Integrated Baseboard Manage

Pagina 61 - Compliance Requirements

Cisco UCS C22 M3 High-Density SFF Rack-Mount Server8CONFIGURING the SERVERCONFIGURING the SERVERFollow these steps to configure the Cisco UCS C22 M3 H

Pagina 62

Cisco UCS C22 M3 High-Density SFF Rack-Mount ServerCONFIGURING the SERVER9STEP 1 VERIFY SERVER SKUVerify the product ID (PID) of the server as shown i