CISCO CONFIDENTIAL
6
Cisco BTS 10200 Softswitch — Release Notes for Release 3.3 V04
OL-1835-04
New and Changed Information
Provisioning the Cisco BTS 10200 Softswitch to Generate EMs
These steps provision the Cisco BTS 10200 Softswitch to generate EMs.
Note The value for id shown in this section (CA146) is an example.
Step 1 Login to a CLI session on the Cisco BTS 10200 Softswitch.
Step 2 Use the following command to display the current values for the call-agent-profile table:
show call-agent-profile id=CA146;
where:
• id—Domain name of the specific Call Agent (CA), in the format CAnnn, where nnn = 3-digit
number previously assigned to the CA. This value is case-sensitive (for example, CA146 and ca146
are not the same). This is the unique identifier for this Call Agent (CMS) node, which was
permanently assigned at time of software installation on the Cisco BTS 10200 Softswitch.
Step 3 If the system response indicates that this table does not exist, then you must create it using the following
command. Otherwise, the EM function is not supported and EMs will not be generated.
add call-agent-profile id=CA146; cdb-billing-supp=N; em-billing-supp=Y;
Caution If the call-agent-configuration table is not created, the Cisco BTS 10200 Softswitch will generate CDBs
but not EMs.
Step 4 If the call-agent-profile table already exists, check (in the display from Step 2) to see if cdb-billing-supp
is set to N (no) and em-billing-supp is set to Y (yes). If not already shown in the display, enable EM
billing support by entering the following command:
change call-agent-profile id=CA146; cdb-billing-supp=N; em-billing-supp=Y;
where:
• cdb-billing-supp—Specifies whether to generate Call Detail Blocks (CDBs). The value of this
optional token is a single ASCII character (Y or N); the default value is Y (yes). The value of this
token must be set to N (no) if the Cisco BTS 10200 Softswitch is to provide event message
generation.
• em-billing-supp—Specifies whether to generate PacketCable event messages. The value of this
optional token is a single ASCII character (Y or N); the default value is N (no). The value of this
token must be set to Y (yes) if the Cisco BTS 10200 Softswitch is to provide event message
generation.
Caution Be sure the system is configured to generate either EMs, and not CDBs. Attempting to generate both
types of records simultaneously can significantly degrade the call processing rate.
Step 5 Enter the following command to generate EMs based on CMS and MGC logical network elements, and
to specify the financial entity ID.
Comentarios a estos manuales