TANDBERG TANDBERG and Cisco CallManager
D13907.01
18
5 TANDBERG Gatekeeper and Cisco CallManager
As discussed previously, registering H.323 endpoints to the Cisco CallManager will limit the functionality
of the H.323 endpoint. These limitations can be prevented, however, by integrating an H.323 gatekeeper
into the SCCP setup instead of the endpoints directly. The gatekeeper is installed into CallManager by
configuring an H.225 trunk and registering the trunk directly to the gatekeeper.
Note: A gatekeeper is central part of the H.323 infrastructure. It provides address translation to the
network for H.323 terminals, Gateways and MCU’s.
There are no specific requirements for the configuration of the TANDBERG Gatekeeper to be able to
register a CallManager trunk to it. But be aware that authentication is not supported in this setup and if the
gatekeeper is configured with an allow/deny list make sure that the Trunk is registered in this list or it will
cause the gatekeeper to reject the registration. This chapter describes how to configure the CallManager so
that it is possible to place calls between the H.323 network and the SCCP network, to do this the following
settings has to be configured within Cisco CallManager:
H225 trunk (gatekeeper controlled)
Route group
Route list
Route pattern
Note: Routing calls between H.323 and SCCP is done by prefixes and route patterns, so before you start
doing the necessary configurations on the CallManager it is recommended to make a number.