Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 8 Provisioning with TL1
8.8 Set Alarm Thresholds
sidtidname
2002-07-11 11:16:10
M 125 COMPLD
"EQPT:MAXCTMP,,,65"
"EQPT:MAXCTMPHYST,,,5"
"EQPT:MINCTMP,,,10"
"EQPT:MINCTMPHYST,,,2"
"PWR-A:PWRBUSMIN,,,420"
"PWR-A:PWRBUSMAX,,,570"
"PWR-B:PWRBUSMIN,,,420"
"PWR-B:PWRBUSMAX,,,570"
;
To set the alarm thresholds, use the SET-TH-DWDM and SET-TH-EQPT commands (see the
“9.6.46 SET-TH-DWDM” section on page 9-71 and the “9.6.47 SET-TH-EQPT” section on
page 9-72). Alarm threshold attributes are described in Table 8-1.