Cisco 15216 EDFA2 Especificaciones Pagina 192

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 252
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 191
9-28
Cisco ONS 15216 EDFA2/EDFA2-A Operations Guide, R2.4
July 2004
Chapter 9 TL1 Commands
9.6.17 INIT-SYS
9.6.17 INIT-SYS
Command Types INIT-SYS
Reboots the system.
Syntax Description
INIT-SYS:[<tid>]:<aid>:<ctag>::<ph>;
LPOUTCHGD “Loss of Output Power Setpoint Changed”
(cerent15216EdfaLpoutSetpoint).
LPOUTDEVCHGD “Lpout (loss of output power) Deviation Changed”
(cerent15216EdfaLpoutDeviation).
LPOUTHYSTCHGD “Lpout (loss of output power) Hysteresis Changed”
(cerent15216EdfaLpoutHysteresis).
MAXCTMPCHGD “Max Case Temperature Changed
(cerent15216EdfaCtmpMax).
MAXCTMPHYSTCHGD “Max Ctmp (case temperature) Hysteresis Changed”
(cerent15216EdfaCtmpMaxHysteresis).
MINCTMPCHGD “Min Case Temperature Changed
(cerent15216EdfaCtmpMin).
MINCTMPHYSTCHGD “Min Ctmp (case temperature) Hysteresis Changed”
(cerent15216EdfaCtmpMinHysteresis).
PREATTCHGD “Pre-attenuation Changed”
(cerent15216EdfaVariableGainPreAttenuation).
PWRBUSMAXCHGD “Power Bus Max (voltage) Changed”
(cerent15216EdfaPowerBusDCVoltageMax).
PWRBUSMINCHGD “Power Bus Min (voltage) Changed”
(cerent15216EdfaPowerBusDCVoltageMin).
PWRBUSMODE “Power Bus Mode Changed”
(cerent15216EdfaPowerBusMode).
SEVERITYCHGD “Severity Changed from CR|MJ|MN|NA|NR to
CR|MJ|MN|NA|NR”.
SFTWDOWNERR “Software Load Error”.
SOFTWARERESET “Software Reset” (cerent15216EdfaOpReset).
SOFTWARERESETERR “Software Reset Error”
(cerent15216EdfaActionOpResult).
ALL Any or all of the preceding (command input only).
NULL Defaults to ALL.
Table 9-22 INH-MSG-ALL Syntax Description (continued)
Parameter Syntax Description
Vista de pagina 191
1 2 ... 187 188 189 190 191 192 193 194 195 196 197 ... 251 252