Cisco 7300-6T3 Especificaciones Pagina 48

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 47
4-14
Cisco 7304 6-Port Clear Channel E3 Line Card Installation and Configuration
OL-5061-01
Chapter 4 Configuring the 6E3 Line Card
Checking the Configuration
Cisco 7304 Routers
Following is an example of the show interfaces command for Cisco 7304 routers. In this example, the
serial interfaces (0 to 5) are on a 6E3 line card in slot 1, also, the status information for interfaces 1
through 5 is omitted. (Interfaces are administratively shut down until you enable them.)
Router #sho interfaces serial 2/1
Serial2/1 is up, line protocol is up
Hardware is Packet over E3
Internet address is 150.2.2.1/24
MTU 4470 bytes, BW 34009 Kbit, DLY 200 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation HDLC, crc 16, loopback set
Keepalive not set
Last input 21:04:19, output 21:04:19, output hang never
Last clearing of "show interface" counters 16:31:30
Input queue:0/75/0/0 (size/max/drops/flushes); Total output drops:15263
Queueing strategy:fifo
Output queue:0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 IP multicast)
0 runts, 0 giants, 0* throttles
0 parity
0 input errors, 0 CRC, 0 frame, 0 overrun,, 0 abort
505603671 packets output, 48537952992 bytes, 0 underruns
0 output errors, 0 applique, 0 interface resets
0 output buffer failures, 0 output buffers swapped out
0 carrier transitions
(Additional display test omitted from this example.)
E3 Alarm and Event Detection
This section assumes that you are familiar with E3 alarms and line states. The 6E3 line card does not
have an LED for alarm and event detection. However, you can enter the show controllers serial slot/port
EXEC command to verify whether the alarm and event detection messages are active or inactive. Most
alarm and event detection messages are short-lived, because if problems occur, the line card clears the
error condition, but records the event to verify line card operation status.
The output from the show controllers serial slot/port EXEC command sends messages about the
following types of alarms and events:
AIS (Alarm Indication Signal)
LOF (Loss of Frame)
LOS (Loss of Signal)
RAI (Remote Alarm Indication)
OOF (Out of Frame)
Vista de pagina 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 54

Comentarios a estos manuales

Sin comentarios