Indicators Per-port status LEDs: link integrity, disabled, activity, speed, and full-duplex indications
System status LEDs: system, RPS, and bandwidth utilization indications
Dimensions and
Weight (H x W x D)
2.63 x 17.5 x 15.9 in. (6.7 x 44.5 x 40.4 cm) (Catalyst 3550-12G and 3550-12T)
1.75 x 17.5 x 17.4 in (4.45 x 44.5 x 44 cm) (Catalyst 3550-24 PWR)
1.75 x 17.5 x 14.4 in. (4.45 x 44.5 x 36.6 cm) (Catalyst 3550-24 and 3550-24-DC)
1.75 x 17.5 x 16.3 in. (4.45 x 44.5 x 41.3 cm) (Catalyst 3550-24-FX and 3550-48)
1.5 RU high (Catalyst 3550-12G and 3550-12T)
1.0 RU high (Catalyst 3550-48 and 3550-24, 3550-24 PWR, 3550-24-DC and 3550-24-FX)
16 lb (7.3 kg) (Catalyst 3550-12G and 3550-12T)
14 lb (6.35 kg) (Catalyst 3550-24 PWR)
11 lb (5.0 kg) (Catalyst 3550-24 and 3550-24-DC)
12 lb (5.5 kg) (Catalyst 3550-24-FX)
13 lb (5.9 kg) (Catalyst 3550-48)
Environmental
Ranges
Operating temperature: 32˚ to 113˚F (0˚ to 45˚C)
Storage temperature: 13˚ to 158˚F (25˚ to 70˚C)
Operating relative humidity: 10 to 85% (non-condensing)
Operating altitude: Up to 10,000 ft (3,049 m)
Storage altitude: Up to 15,000 ft (4,573 m)
Power Requirements Power consumption: 190 W (maximum), 650 BTUs per hour (Catalyst 3550-12G and
3550-12T); 525W (maximum), 1790 BTUs per hour (Catalyst 3550-24 PWR); 65 W
(maximum), 222 BTUs per hour (Catalyst 3550-24); 110 W (maximum), 375 BTUs per hour
(Catalyst 3550-48); 72 W (maximum), 250 BTUs per hour (Catalyst3550-24-DC); 85 W
(maximum), 290 BTUs per hour (Catalyst 3550-24-FX)
AC input voltage/frequency: 100 to 127/200 to 240 VAC (auto-ranging), 50 to 60 Hz
DC Input Voltages
RPS input +12V @ 13A (Catalyst 3550-12G, 3550-12T, and 3550-48); +12V @ 8.3A (Catalyst
3550-24 and 3550-24-FX); +12V @ 7.5A and – 48V @ 7.8A (Catalyst 3550-24 PWR)
DC input for 3550-24-DC: -36 to 72VDC @ 2A
Acoustic Noise ISO 7770, bystander position operating to an ambient temperature of 30 degrees Celsius:
Catalyst 3550-12G and 3550-12T: 58 dBa
Catalyst 3550-24 and 3550-24-DC: 48 dBa
Catalyst 3550-48 and 3550-24-FX: 46 dBa
Catalyst 3550-24 PWR: 47 dBa
Mean Time Between
Failure (MTBF)
110,332 hours (Catalyst 3550-12G)
113,658 hours (Catalyst 3550-12T)
166,356 hours (Catalyst 3550-24 PWR)
193,000 hours (Catalyst 3550-24)
163,000 hours (Catalyst 3550-48)
183,000 hours (Catalyst 3550-24-DC)
186,000 hours (Catalyst 3550-24-FX)
Table 2 Product Specifications (Continued)