Cisco IE 3010 Switch Getting Started Guide
78-19582-02
Cisco IE 3010 Switch Getting Started Guide
DC power:
Insert the positive wire into the terminal
screw labeled +, and the negative wire into
the terminal screw labeled .
Make sure that you cannot see any wire lead.
Only wire with insulation should extend from
the terminal screw.
Note If you have a low-voltage DC power
supply module, connect the wires to
the terminal screws labeled Lo. If you
have a high-voltage DC power supply
module connect the wires to the
terminal screws labeled Hi.
Step 9
Torque the captive screws (above the installed wire leads) to 8.5 in-lb (± 0.5 in-lb).
Step 10
AC power:
Connect the other end of the line wire (the one connected to L) to the line terminal on the
AC-power source, and connect the other end of the neutral wire (the one connected to N) to
the neutral terminal on the AC power source.
DC power:
Connect the other end of the positive wire (the one connected to +) to the positive terminal
on the DC power source, and connect the other end of the negative wire (the one connected
to ) to the negative terminal on the DC power source.
Step 11
When you are testing the switch, one power connection is sufficient. If you are installing the
switch and are using a second power source, repeat Step 3 through Step 10.
Step 12
Close the power-input terminal cover. Use a ratcheting torque screwdriver to torque the screw
to 6–8 in-lb.
Cisco IE 3010