Cisco ONS 15327 Product Overview, R3.3
June 2002
Cisco ONS 15327 Product Overview
Alarm Collection and Display
The history feature displays historical alarm data and also shows events
(non-reported activities) that have occurred, such as performance monitoring
threshold crossings or protection switching events. The CTC History tab uses
subtabs to present two alarm history views:
The Session subtab presents alarms and events for the current CTC session.
When you log off, the alarms disappear.
The Node subtab shows the alarms and events that occurred at the node since
the CTC software installation. The ONS 15327 can store up to 256 critical
alarms, 256 major alarms, 256 minor alarms, and 256 events. When the limit
is reached, the ONS 15327 discards the oldest alarms and events.
Alarm Profiles
The ONS 15327 includes an alarm profile feature. This allows you to change the
default alarm severities (for example, change an alarm severity from minor to
major) and apply the new severities at the card, port, node, or network level.