Unit with front bezel
and SEPS/PS
– 16.75 in. (42.55 cm) 16.75 in. (42.55 cm) 16.75 in. (42.55 cm) 16.75 in. (42.55 cm) 16.75 in. (42.55 cm)
Weight 8.5 lb (3.9 kg) 27 lb (12.3 kg) 28 lb (12.7 kg) 28 lb (12.7 kg) 33 lb (15 kg) 33 lb (15 kg)
Table 8. Power Type and Requirements
Concentrator Cisco VPN 3005 Cisco VPN 3015, 3020, 3030, 3060, and 3080
Nominal 15W (51.22 BTU/hr) 35W (119.50 BTU/hr)
Maximum 25W (85.36 BTU/hr) 50W (170.72 BTU/hr)
Input Voltage 100 to 240 VAC 100 to 240 VAC
Frequency 50/60 Hz 50/60 Hz
Power Factor Correction Universal Universal
Environmental
●
Operating temperature: 32 to 131°F (0 to 55°C)
●
Non-operating temperature: –4 to 176°F (–40 to 70°C)
●
Humidity: 0 to 95 percent, non-condensing
Regulatory Compliance
●
CE Marking
Safety
●
UL 1950, CSA
EMC
●
FCC Part 15 (CFR 47) Class A, EN 55022 Class A, EN50082-1, AS/NZS 3548 Class A, VCCI Class A