Table 4 Cisco AS5400 Environmental Data
Feature Benefit
NEBS Certification Telcordia SR-3580 Level 3 certification based on usage and critical nature of
equipment
ETSI Certification • ETS 300386-2
• ETS 300 019 (series)
• EMC in public telecommunications centers
• Mechanical/environmental requirements
Normal Operating Conditions • 0 to 40 C
• 200- to 10,000-ft. elevation
Safety Certifications • UL 1950, third edition
• CSA 950, third edition
• EN 60950, with amendments 1, 2, and 3
• IEC 950
• AS/NZS 3260
• TS 001
Electromagnetic Emissions Certifications • EN 55022B
• NZ/AS3548B
• VCCI II
• FCC A
Immunity Certifications • 1000-4-2 (electrostatic discharge)
• 1000-4-3 (radiated emissions)
• 1000-4-4 (electrical fast transients)
• 1000-4-5 (surge)
• 000-4-6 (conducted emissions)
Level 3 standalone
Environmental Specifications • Heat dissipation • 683-870 Btu/hr
• AC power cable supplied, dual cables for redundant version • 12 American wire gauge (AWG), 15 amp IEC standard cable
• DC • 12 AWG, 2 pairs (black and red)
• Storage temperature • 25.8 to 185 F (-40 to 85 C)
• Operating temperature (air inlet to power unit) • 20 to 50 C airflow front to back
• Acoustics • 60 dBA typical; sound pressure level at 1m
• Humidity (noncondensing) • 5 to 95 percent
• Altitude • 200 to 10,000 ft.
• Reliability (at 40 C, 200 VAC, 1600W) • 7500 FITS per TR-EOP-000332
• 1.5 x 105 hours MTBF per RIN
Table 5 Cisco AS5400 Mechanical Data
Dial Shelf • Dimensions (H x W x D)
• Weight
• 3.4 x 17.5 x 18.25 in.
• 32 lb (12 kg)