Cisco UCS C460 M2 High-Performance Rack-Mount Server
20
CONFIGURING the SERVER
STEP 5 CHOOSE RAID CONFIGURATION
The C460 M2 server accommodates either an LSI MegaRAID SAS 9260-8i or LSI MegaRAID SAS
9240-8i RAID controller. The C460 M2 contains a drive bay housing up to 12 HDDs or SSDs.
Cisco can provide factory-configured RAID 0, 1, 5, 6, and 10 systems depending on the RAID
implementation chosen, the RAID controller chosen, and the number of drives ordered.
Factory-configured RAID options are listed at the end of
Table 7. Note that RAID levels 50 and
60 are supported on the 9260-8i, but are not factory configurable.
Choose RAID Options
Choose one RAID controller, one RAID configuration option, and, if desired, the battery backup
option listed in
Table 7.
Table 7 Available RAID Options
Product ID (PID) PID Description
RAID Controllers
RC460-PL001 LSI MegaRAID SAS 9260-8i (RAID 0, 1, 5, 6, 10, 50, 60 supported)
■ Plugs into the dedicated SAS riser on the rear of the server on the left (see
Figure 4 on page 6).
■ Supports from 1 to 12 internal SAS or SATA drives
■ Battery backup option available (see the battery backup PID section in this
table)
■ Factory-configured RAID options: RAID 0, 1, 5, 6, 10 (see the RAID PIDs
section in this table)
RC460-PL002 LSI MegaRAID SAS 9240-8i (RAID 0 and 1)
■ Plugs into the dedicated SAS riser on the rear of the server on the left (see
Figure 4 on page 6).
■ Supports from 1 to 8 internal SAS or SATA drives
■ Battery backup option not available
■ Factory-configured RAID options: RAID 0 and 1 (see the RAID PIDs section in
this table)
RAID Battery Backup Option
R2XX-LBBU2 Battery Backup (for LSI MegaRAID SAS 9260-8i controller only)
RAID Configuration
R2XX-RAID0 Factory pre-configured RAID striping option
Enable RAID 0 Setting. Requires a minimum of 1 hard drive.
R2XX-RAID1 Factory pre-configured RAID mirroring option
Enable RAID 1 Setting. Requires exactly 2 drives, with same size, speed, capacity.
Comentarios a estos manuales