Cisco 15454-TCC - Network Processor Card Especificaciones Pagina 55

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 334
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 54
1-21
Cisco ONS 15454 Troubleshooting and Maintenance Guide
November 2001
Chapter 1 Alarm Troubleshooting
Step 5 If the software reset does not clear the card, physically reseat the TCC+ card to perform a card pull.
Step 6 If the alarm still does not clear, replace the TCC+ card.
Note When you replace a card with an identical type of card, you do not need to make any changes
to the database.
1.3.29 CONTBUS-B-18
Major, Non-service affecting
The main processor on the TCC+ card in Slot 11 lost communication with the coprocessor on the TCC+
card in Slot 7. The problem is with the physical path of communication from the TCC+ card to the
reporting TCC+ card. The physical path of communication includes the two TCC+ cards and the
backplane.
Caution Always use the supplied electrostatic discharge wristband when working with a powered ONS 15454.
Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf
assembly.
Procedure: Clear the CONTBUS-B-18 Alarm on the TCC+ Card
Step 1 Position the cursor over the TCC+ card in Slot 11.
Step 2 Right-click and choose RESET CARD to make the TCC+ in Slot 11 the active TCC+ card.
Step 3 Wait approximately 2 minutes for the TCC+ in Slot 7 to reset as the standby TCC+ card.
Step 4 Position the cursor over the TCC+ card in Slot 7.
Step 5 Right-click and choose RESET CARD again to make the TCC+ in Slot 11 the active TCC+ card.
Step 6 If the alarm reappears when the TCC+ in Slot 11 reboots as the active TCC+, the TCC+ card in Slot 11
is defective and must be replaced.
Note When you replace a card with an identical type of card, you do not need to make any changes
to the database.
1.3.30 CTNEQPT-PB1PROT
Critical, Service affecting
An Interconnection Equipment Failure - Standby Payload Bus alarm occurs when digital traffic is being
lost between the cross-connect (XC/XCVT/XC10G) card and the reporting traffic card.
Vista de pagina 54