Vista de pagina 506
2-481
Catalyst 2950 and Catalyst 2955 Switch Command Reference
0L-10102-02
Chapter 2 Catalyst 2950 and 2955 Cisco IOS Commands
storm-control
Command Modes Interface configuration
Command History
Usage Guidelines Use the storm-control command to enable or disable broadcast, multicast, or unicast storm control on
a port. After a port is disabled during a storm, use the no shutdown interface configuration command to
enable the port.
The suppression levels can be entered as a percentage of total bandwidth. A suppression value of
100
percent means that no limit is placed on the specified traffic type. This feature is enabled only when
the rising suppression level is less than 100 percent. If no other storm-control configuration is specified,
the default action is to filter the traffic causing the storm and to send no SNMP trap.
If your switch is a non-LRE Catalyst 2950 switch, the suppression levels can also be entered as the rate
at which traffic is received in packets per second. A suppression value of 4294967295 packets per second
means that no limit is placed on the specified traffic type. This feature is enabled only when the rising
suppression level is less than 4294967295 packets per second. If no other storm-control configuration is
specified, the default action is to filter the traffic causing the storm and to send no SNMP trap.
When a storm occurs and the action is to filter traffic, if the falling suppression level is not specified, the
switch blocks all traffic until the traffic rate drops below the rising suppression level. If the falling
suppression level is specified, the switch blocks traffic until the traffic rate drops below this level.
When a multicast or unicast storm occurs and the action is to filter traffic, the switch blocks all traffic
(broadcast, multicast, and unicast traffic) and sends only Spanning Tree Protocol (STP) packets.
When a broadcast storm occurs and the action is to filter traffic, the switch blocks only broadcast traffic.
The trap and shutdown options are independent of each other.
If you configure the action to be taken when a packet storm is detected as shutdown (the port is
error-disabled during a storm), you must use the no shutdown interface configuration command to bring
the interface out of this state. If you do not specify the shutdown action, specify the action as trap (the
switch generates a trap when a storm is detected).
Examples This example shows how to enable broadcast storm control on a port with a 75.67-percent rising
suppression level:
Switch(config-if)# storm-control broadcast level 75.67
This example shows how to enable multicast storm control on a port with a 87-percent rising suppression
level and a 65-percent falling suppression level:
Switch(config-if)# storm-control multicast level 87 65
This example shows how to enable multicast storm control on a port with a 2000-packets-per-second
rising suppression level and a 1000-packets-per-second falling suppression level on a non-LRE
Catalyst
2950 switch:
Switch(config-if)# storm-control multicast level pps 2000 1000
Release Modification
12.1(6)EA2 This command was introduced. It replaced port storm-control command.
12.1(14)EA1 The pps pps pps-low option was added.
12.1(22)EA2 The pps-low option was made optional.
Vista de pagina 506
1 2 ... 502 503 504 505 506 507 508 509 510 511 512 ... 673 674

Comentarios a estos manuales

Sin comentarios

Hearth-and-home-technologies GARNET-MBK Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Ofen Hearth-and-home-technologies GARNET-MBK.
Wir stellen 1 PDF-Handbücher Hearth-and-home-technologies GARNET-MBK zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Bedienungsanleitung


Inhaltsverzeichnis

GARNET-T

1

Portland

2

- TABLE OF CONTENTS

3

Listing and Code Approvals

4

ּCSA 2.33a-2003ּ

4

ּCAN/CBA 2.17-M91

4

Massachusetts

5

Getting Started

6

B. Clearances

7

Termination Locations

8

Figure 4.4

9

Alcove Applications

9

Figure 5.1

10

Figure 5.2

11

VERTICAL DISTANCE

11

FROM APPLIANCE TO

11

90° ELBOW

11

Figure 5.4

12

Figure 5.3

12

Figure 5.5

13

Figure 5.6

13

Figure 5.9

14

Figure 5.8

14

Figure 5.7

14

Figure 5.10

15

Figure 5.11

15

Figure 5.13

16

Figure 5.14

16

Figure 5.12

16

Figure 5.15

17

Figure 5.16

17

Figure 5.17

18

Figure 5.18

18

Figure 5.19

18

Figure 5.22

19

Figure 5.23

19

Figure 5.20

19

Figure 5.21

19

Alcove Clearance to

20

Combustibles must

20

Figure 5.25

21

Figure 5.26

21

Figure 5.28

22

Figure 5.27

22

Figure 5.29

22

Figure 5.30

22

Slim Line Wall Thimble

23

Figure 5.33

24

Gas Information

25

Mounting Screws

26

Pressure Regulator Tower

26

Diaphragm

26

B. Gas Pressures

27

C. Gas Connection

27

Electrical Information

29

Figure 7.1

30

Appliance Setup

31

D. Accessories

32

E. Positioning the Logs

32

F. Mineral Wool

32

H. Blower Installation

33

G. Glass Replacement

33

SNAP DISC

34

TERMINALS

34

September 1, 2008

35

Operating Instructions

37

LIGHTING INSTRUCTIONS

38

TO TURN OFF GAS TO APPLIANCE

38

D. After Appliance is Lit

39

ISSUE SOLUTIONS

39

Troubleshooting

40

Inspect Maintenance Tasks

43

A. Maintenance Tasks

43

Reference Materials

44

B. Vent Components Diagram

45

C. Vent Components List

46

- 46DVA-ES 4DT-OS - SV4SU

47

Page 52

52

G. Homeowner’s Notes

53

4021-645A 09-01-08

54

Your Records for Model:

56





Weitere Produkte und Handbücher für Ofen Hearth-and-home-technologies

Modelle Dokumententyp
BAY-40 Bedienungsanleitung   Hearth and Home Technologies BAY-40 User Manual, 52 Seiten
GATEWAY Bedienungsanleitung   Hearth and Home Technologies GATEWAY User Manual, 48 Seiten
C-40 Bedienungsanleitung   Hearth and Home Technologies C-40 User Manual, 72 Seiten
EPA Certified Woodburning Fireplace 7100FP-GD-B Bedienungsanleitung   Hearth and Home Technologies EPA Certified Woodburning Fireplace 7100FP-GD-B User Manual, 72 Seiten
B-Vent Gas Appliance CB4842IR Bedienungsanleitung   Hearth and Home Technologies B-Vent Gas Appliance CB4842IR User Manual, 40 Seiten
4100I-GD-B Bedienungsanleitung   Hearth and Home Technologies 4100I-GD-B User Manual, 28 Seiten
WTBC42DB Bedienungsanleitung   Hearth and Home Technologies WTBC42DB User Manual, 4 Seiten
6000GLX-IPI-R Bedienungsanleitung   Hearth and Home Technologies 6000GLX-IPI-R User Manual, 72 Seiten
GAS STOVE L-CORNER-TRC Bedienungsanleitung   Hearth and Home Technologies GAS STOVE L-CORNER-TRC User Manual, 40 Seiten
EL36 Series Bedienungsanleitung   Hearth and Home Technologies EL36 Series User Manual, 52 Seiten
Birmingham Bedienungsanleitung   Hearth and Home Technologies Birmingham User Manual, 4 Seiten
Heatilator GDST5244I Bedienungsanleitung   Hearth and Home Technologies Heatilator GDST5244I User Manual, 60 Seiten
Balanced Flue Gas Fireplace CORNER-HVB-CE Bedienungsanleitung   Hearth and Home Technologies Balanced Flue Gas Fireplace CORNER-HVB-CE User Manual, 2 Seiten
FB-IN-S Bedienungsanleitung   Hearth and Home Technologies FB-IN-S User Manual, 44 Seiten
A42R Bedienungsanleitung   Hearth and Home Technologies A42R User Manual, 48 Seiten