Connecting the ICIM to Additional
Chassis
ICIM IN and ICIM OUT Connectors
Every chassis has a DB9 ICIM IN and a DB9 ICIM OUT connector for the
purpose of chassis-to-chassis ICIM2 connections. ICIM IN is a female
connector and ICIM OUT is a male connector.
The cable required for both ICIM IN and ICIM OUT connections is a
shielded 9-wire serial extension cable, DB9 Female to DB9 Male. Cisco #
180143 CIFA# 144856
All chassis connected in this daisy-chain must have a unique chassis ID
number.
If the ICIM OUT terminator (4013014) that ships with the ICIM is not
installed on the last chassis of a daisy-chain connection, faulty
communication with the ICIM may occur.
The ICIM OUT port of the last chassis in the daisy-chain must be
terminated with an ICIM OUT terminator, part number 4013014