Cisco Prisma II Hybrid Amplifier Información técnica Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 124
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
© 2006 Cisco Systems, Inc. All rights reserved. Cisco Confidential Presentation_ID Kirkpatrick 092509
15
Checking the Operating Status using the
ICIM2
You can use the ICIM to check status of all operating parameters of a module. All
status information is displayed on the ICIM LCD.
1 At the MAIN menu, press the key to highlight the Shelf and Slot fields.
2 Press the key to address the Shelf number. Then press the key or the
key to scroll to the number of the desired shelf.
3 Press the key. The Slot field is highlighted.
4 Press the key or the key to scroll to the number of the desired slot.
5 Press the key. The MODULE menu appears on the ICIM LCD.
6 Press the key.
7 Press the key or the key to scroll through the monitored parameters
until you find the parameter of interest.
8 Check the status of the desired parameter or select other parameters to monitor.
When finished, press the key to return to the MAIN menu
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 123 124

Comentarios a estos manuales

Sin comentarios