Cisco 3520 Guía de instalación Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
25
Release Notes for the Catalyst 3750 Switch Cisco IOS Release 12.1(14)EA1
OL-4215-01
Open Caveats
CSCeb66720
When CDP is disabled on a stack member interface and that interface is converted to a routed port
or switch port, CDP is re-enabled on the stack member interfaces. Having CDP enabled on a stack
member but not on the stack master can cause the 802.1X voice VLAN and inline power features to
fail on the stack member.
The workaround is to enable and then disable CDP on the interface.
CSCeb69078
Executing remote commands on a Catalyst 3750-12S switch that is unpacking and copying a new
software image to Flash memory can cause the software upgrade to fail.
The workaround is to reload the switch to re-enable Flash operations, and then repeat the software
upgrade procedure.
Open CMS Caveats
These are the severity 3 CMS configuration caveats:
CSCdz01037
CMS fails when a switch is running the crypto software image and the vty lines have been
configured to use only secure shell (SSH) using the transport input ssh and line vty 0 15 global
configuration commands.
The workaround is to allow SSH and Telnet access through the vty lines by using the transport
input ssh telnet and line vty 0 15 global configuration commands.
CSCeb05183
The Port Settings table displays meaningless information in the columns for interface description
and duplex cells. This problem occurs for some of the Catalyst 2820 and Catalyst 1900 switches.
There is now workaround.
CSCeb23334
CMS does not validate configuration values for STP port priority before applying them to the switch.
When invalid values are applied, the attempt fails silently without a warning message. This applies
to all switches running Cisco IOS Release 12.1 or later.
There is no workaround. Make sure that configuration values are valid.
CSCeb23416
CMS does not validate configuration values for STP port path cost before applying them to the
switch. When invalid values are applied, the attempt fails silently without a warning message. This
applies to all switches running Cisco IOS Release 12.1 or later.
There is no workaround. Make sure that configuration values are valid for the switch type.
CSCeb23592
CMS does not validate configuration values for STP bridge parameters before applying them to the
switch. When invalid values are applied, the attempt fails silently without a warning message. This
applies to all switches running Cisco IOS 12.1 or later.
There is no workaround. Make sure that configuration values are valid.