5-17
Cisco XR 12404 Router Installation Guide
OL-13830-02
Chapter 5 Maintaining the Router
Removing and Replacing a DC Power Entry Module
Step 1 If the Input OK and Output OK LEDs are off, or if the Output Fail LED is on,
make sure that the:
PEM is firmly seated in the bay and the captive screws are tightened securely.
AC power source circuit breaker is switched on.
Power cord is firmly plugged into the AC power source receptacle.
Power cord is firmly plugged into the PEM and the bail latch is secure over
the plug.
Power switch is set to the on (1) position.
Step 2 If the problem still exists after checking the items in Step 1, replace the PEM.
If replacing the PEM does not correct the proble
m, contact a Cisco service
representative for assistance.
Removing and Replacing a DC Power Entry Module
Although a DC PEM supports OIR, in order to maintain operational redundancy,
proper cooling, and meet EMI compliance standards, you must have both working
power supplies installed. When you remove a failed power supply with the router
in operation, perform the replacement as quickly as possible. Make sure you have
the tools and the replacement power supply ready before beginning the removal
and installation procedure.
Refer to Fi
gure 5-11 and use the following procedure to remove and replace a
DC PEM.
1 Input OK Green On The PEM is powered on and operating
co
rrectly.
2 Output OK Green On The AC power source is present and operating
wit
hin the specified limit.
3 Output Fail Amber On The PEM detects a fault condition causing it
to sh
utdown.