18 Cisco 3600 Series Power Supply Configuration Note
Replacing Connections to the Router
If you have a DC-powered router, rewire the DC-input power supply (38 to 72 VDC) to
the terminal block using 14 AWG copper wires. The proper wiring sequence is ground to
ground, positive to positive, and negative to negative. (See Figure 20 and Figure 21.)
Warning This product relies on the building’s installation for short-circuit (overcurrent) protection.
Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international)
is used on the phase conductors (all current-carrying conductors). (To see translated versions of this
warning, refer to the Regulatory Compliance and Safety Information document that accompanied the
router.)
Warning When stranded wiring is required, use approved wiring terminations, such as closed-loop
or spade-type with upturned lugs. These terminations should be the appropriate size for the wires
and should clamp both the insulation and conductor. (To see translated versions of this warning, refer
to the Regulatory Compliance and Safety Information document that accompanied the router.)
Warning The illustration shows the DC power supply terminal block. Wire the DC power supply
using the appropriate lugs at the wiring end, as illustrated. The proper wiring sequence is ground to
ground, positive to positive (line to L), and negative to negative (neutral to N). Note that the ground
wire should always be connected first and disconnected last. (To see translated versions of this
warning, refer to the Regulatory Compliance and Safety Information document that accompanied the
router.)
Caution Do not overtorque the terminal block captive thumbscrew or terminal block contact
screws. The recommended torque is 8.2 ± 0.4 inch-lb.
Warning After wiring the DC power supply, remove the tape from the circuit breaker switch
handle and reinstate power by moving the handle of the circuit breaker to the ON position. (To see
translated versions of this warning, refer to the Regulatory Compliance and Safety Information
document that accompanied the router.)
Figure 20 Cisco 3620 DC-Input Power Supply Connections
+-
Terminal
block
Negative
H7477
Positive
Ground
On/off
switch