12
Grounding the Chassis
You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance with local electrical
safety standards.
• For NEBS-compliant grounding, use size AWG 6 (13 mm
2
) wire and the ground lug provided in the accessory kit.
• For NEC-compliant grounding, use size AWG 14 (2 mm
2
) or larger wire and an appropriate user-supplied ring terminal.
• For EN/IEC 60950-compliant grounding, use size AWG 18 (1 mm
2
) or larger wire and an appropriate user-supplied ring
terminal.
To connect the chassis to a reliable earth ground, perform the following steps:
Step 1 Strip one end of the ground wire to the length required for the ground lug or terminal.
• For the NEBS ground lug—approximately 0.75 in. (20 mm)
• For user-provided ring terminal—as required
Step 2 Crimp the ground wire to the ground lug or ring terminal, using a crimp tool of the appropriate size.
Step 3 Attach the ground lug or ring terminal to the chassis as shown in Figure 6 or Figure 7. For the ground lug, use the two
screws with captive locking washers provided. For a ring terminal, use one of the screws provided. Use a number 2
Phillips screwdriver, and tighten the screws to a torque of 8 to 10 in-lb (0.9 to 1.1 N-m).
Step 4 Connect the other end of the ground wire to a grounding point at your site.
Figure 6 NEBS-Compliant Chassis Ground Connection Using Ground Lug
Figure 7 Chassis Ground Connection Using Ring Terminal
4 Connect Cables
Warning
Do not work on the system, or connect or disconnect cables during periods of lightning activity. Statement 1001
82704
SEE MANUAL BEFORE INSTALLATION
AL
CD
LP
RD
TD
SEE MANUAL BEFORE INSTALLATION
DSU
56K
AL
CD
LP
RD
TD
SEE MANUAL BEFORE INSTALLATION
DSU
56K
EN
V0
BANK 4
BANK 3
BANK 2
BANK 1
BANK 0
NM-HDV
VWIC
2MFT-E1
SEE
MANUAL
BEFORE
INSTALLATION
CTRLR E2
CTRLR E1
AL
LP
CD
1
2
Ground lug
103014
SEE MANUAL BEFORE INSTALLATION
AL
CD
LP
RD
TD
SEE MANUAL BEFORE INSTALLATION
DSU
56K
AL
CD
LP
RD
TD
SEE MANUAL BEFORE INSTALLATION
DSU
56K
EN
V0
BANK 4
BANK 3
BANK 2
BANK 1
BANK 0
NM-HDV
VWIC
2MFT-E1
SEE
MANUAL
BEFORE
INSTALLATION
CTRLR E2
CTRLR E1
AL
LP
CD
1
2
Ring terminal
Comentarios a estos manuales