Figure 8 DC Power Connections
Step 5 Install the plastic cover over the terminal block. (See Figure 9.)
Warning
The safety cover is an integral part of the product. Do not operate the unit without the safety cover installed.
Operating the unit without the cover in place will invalidate the safety approvals and pose a risk of fire and
electrical hazards. Statement 117
Step 6 Organize and secure the wires using cable ties as shown in Figure 9.
Step 7 Turn on power to the DC circuit.
Figure 9 Wire Routing and Attachment
Approved Scenarios and Scenarios Not Approved for Dual DC Power Supply Configuration
You can connect a single DC power source to either the A input or the B input. If there are dual power sources, connect one
source to the A input and one source to the B input. Both sources must be the same polarity (with respect to ground) and voltage
(within 0.25 volts). Do not connect –DC grounded and +DC grounded dual sources to a Cisco 3725 series router.
Caution Dual sources with opposite-polarity grounding damage equipment.
In Figure 10, either the positive source terminal or the negative source terminal is tied to ground.
95967
A
+
B
+
A ++B
Terminal
block
Negative DC input Positive DC input
Terminal
block
-DC, input B
Return, input B
Safety ground
Return, input A
-DC, input A
Return, input B
+DC, input B
Safety ground
+DC, input A
Return, input A
95823
AL
CD
LP
BEFORE INSTALLATION
DSU
56K
SEE MANUAL BEFORE INSTALLATION
Cable tie
From DC
power
source
From DC
power
source
Plastic cover