1-52
Cisco ONS 15454 SDH Troubleshooting and Maintenance Guide, R3.3
May 2002
Chapter 1 Alarm Troubleshooting
Alarm Procedures
d. Click Yes on the Confirm Switch dialog box. After the active card goes into standby, the original
standby slot becomes active. This causes the ACT/STBY LED to become green on the former
standby card.
e. If the alarm does not clear after the cross-connect XC10G side switch, perform a software reset on
the reporting card:
f. Display the CTC node view.
g. Position the cursor over the slot reporting the alarm.
h. Right-click to choose RESET CARD.
i. Click Yes at the Resetting Card confirmation dialog.
Wait for the card to reboot.
j. If the alarm persists, physically reseat the reporting I/O card.
1.5.66 SYNCPRI
• Minor, Non-service affecting
A loss of timing on primary reference alarm occurs when the ONS 15454 SDH loses the primary timing
source (reference 1). The ONS 15454 SDH uses three ranking timing references. The timing references
are typically two BITS-level or line-level sources and an internal reference. If SYNCPRI occurs, the
ONS 15454 SDH should switch to its secondary timing source (reference 2). This switch also triggers
the SWTOSEC alarm.
Procedure: Clear the SYNCPRI Condition
Step 1 From the node view, click the Provisioning > Timing tabs.
Step 2 Check the current configuration for the REF-1 of the NE reference.
Step 3 If the primary reference is a BITS input, verify the wiring connection from the ONS 15454 SDH
backplane BITS clock pin fields to the timing source.
Step 4 Check that the BITS clock is operating properly.
Step 5 If the primary reference clock is an incoming port on the ONS 15454 SDH, complete the “LOS (E-N)”
procedure on page 1-40.
1.5.67 SYNCSEC
• Minor, Non-service affecting
A loss of timing on secondary reference alarm occurs when the ONS 15454 SDH loses the secondary
timing source (reference 2). The ONS 15454 SDH uses three ranked timing references. The timing
references are typically two BITS-level or line-level sources and an internal reference. If SYNCSEC
occurs, the ONS 15454 SDH should switch to the third timing source (reference 3) to obtain valid timing
for the ONS 15454 SDH. This switch also triggers the SWTOTHIRD alarm.