Chapter 1 Product Overview
Supervisor Engines
1-10
Cisco 7600 Series Internet Router Module Installation Guide
78-12798-07
LINK
Orange The link has been disabled by software.
Flashing
orange
The link is bad and has been disabled due to a hardware failure.
Green The port is operational.
Off No signal is detected.
1. The SYSTEM and PWR MGMT LED indications on a redundant supervisor engine are synchronized to the active supervisor
engine.
2. VTT = voltage termination module. The VTT module terminates signals on the system switching bus.
3. If no redundant supervisor engine is installed and there is a VTT module minor or major overtemperature condition, the
system shuts down.
Table 1-4 Supervisor Engine 720 LEDs
LED Color Description
STATUS
Orange The module is booting or running diagnostics (normal initialization
sequence).
Green All diagnostics pass; the module is operational (normal initialization
sequence).
Yellow Minor hardware problems.
Red An overtemperature condition has occurred. (A major threshold has
been exceeded during environmental monitoring.)
SYSTEM
1
Orange The module is powering up or a minor hardware fault has occurred.
Red Major hardware problem.
The temperature of the supervisor engine major threshold has been
exceeded.
Blinking
Red
Continuous backplane stall.
Green All chassis environmental monitors are reporting OK.
ACTIVE
Orange The module is powering up or is in standby mode.
Green The module is operational and active.
Table 1-3 Supervisor Engines 1A and 2 LEDs (continued)