Known Issues
16
Known Issues
78-12814-03
CSCdu07314 Some ports on the DPA 7630 are
off-hook after restart.
When connected to an Octel 200 system, some
ports on the DPA 7630 might appear to be in the
“off hook” state while the DPA 7630 is starting
up. Ports also might not answer calls. The Octel
200 reports these ports to be in “NDT” state (via
the pstat command).
This behavior stops shortly after the DPA 7630
has started up and all the ports register
successfully with Cisco CallManager. This occurs
because the Octel system performs a self test on
the ports as they become available. The Octel 200
goes off hook and checks for dial tone.
However, this test might fail while the ports are
registering with the Cisco CallManager. The
Octel will then retry the test after two minutes, by
which time the ports will have stabilized and the
test will pass.
Calls through the DPA 7630 should not be made
until all the Octel 200’s ports that are connected
to the DPA have successfully come up, and are in
“IDL” state (as reported by pstat).
CSCdu14733 During restart, a warning stating
that the Cisco CallManager
connection has gone down
appears for some of the ports on
the DPA 7630/7610.
This can be caused by several factors during the
startup process. However, once all the ports have
come up, the warnings should not re-occur.
You can safely ignore these warnings during the
startup process.
Table 3 DPA 7630/7610 Known Issues (continued)
Bug ID Summary Explanation