17
Known Issues
78-12814-03
Known Issues
CSCuk23263 Pauses in Octel’s MWI set/clear
dial string can cause MWIs to fail
on the DPA 7630.
Pauses in the Octel’s message waiting indicator
activation and deactivation dialing sequences can
cause the DPA 7630 to fail to recognize MWI
commands.
This is caused by a timeout in the DPA 7630 while
it waits for all of the digits in the MWI sequence
to be sent. A long delay in the dialing sequence
causes the DPA7630 to assume the command had
been completed before the Octel dials the rest of
the command, and the MWI command would be
missed by the DPA 7630.
In versions prior to 1.2(1), you can resolve this by
removing any pauses from the dialing sequence
specified in the configuration of the Octel.
In version 1.2(1) and later, the DPA 7630 uses any
pauses in the “Definity MWI ON pre-extension
dial string” and “Definity MWI OFF
pre-extension dial string” menu options from the
Configure > Octel/Definity integration menu.
CSCuk23485 Resetting one of the DPA ports
from Cisco CallManager causes
the DPA 7630/7610 to give a
warning that the port has lost its
connection to Cisco CallManager.
This is expected behavior. Resetting a port causes
the DPA 7630/7610 to immediately drop any calls
on that port. The warning indicates a possible
cause of terminated or lost voice mail calls.
Table 3 DPA 7630/7610 Known Issues (continued)
Bug ID Summary Explanation