There is no change in the
module status because the
power capability is
unchanged.
Power supply is removed
with combined mode
enabled (redundancy
disabled).
System log and syslog
messages are generated.
System power is decreased
to the power capability of
one supply.
If there is not enough power
for all previously
powered−up modules, some
modules are powered down
and marked as power−deny
in the show module
command output status
field.
System is booted with
power supplies of different
wattage, or different types
are installed and
redundancy is enabled or
combined enabled.
System log and syslog
messages are generated.
System power is equal to
the first recognized power
supply.
The power supply
recognized second is kept
in err−disabled mode.
System is booted with
power supplies of equal
wattage and type installed
in combined more
(redundancy disabled).
System log and syslog
messages are generated.
System power is not the
sum of two power supplies.
It is P+ (P * ratio). Refer to
the Available Power for
Catalyst 4500 Series
Switches Power Supplies
section of the product
documentation for more
information.
The system powers−up as
many modules as the
combined capacity allows.
Configuration
The default power supply management mode is to use redundant mode. Issue this command to change the
mode to combined:
Switch (config)#power redundancy−mode combined
Issue this command to change the mode to redundant: