Cisco 4510R - Catalyst Switch Manual de usuario Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 21
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
Switch (config)#power redundancy−mode redundant
Verification
Issue the show power command in order to verify the power supply management mode and to check the
status of the power supply:
C4507−A#show power
Power Fan Inline
Supply Model No Type Status Sensor Status
PS1 PWR−C45−1400AC AC 1400W good good n.a.
PS2 none −− −− −− −−
Power Summary
(in Watts) Available Used Remaining
System Power 1360 220 1140
Inline Power 0 0 0
Maximum Power 1400 220 1180
Power supplies needed by system : 1
!−−− Indicates redundant mode of operation.
The Catalyst 4500 does not support a mix of power supplies of different wattage or types (AC/DC) in the
same chassis. The second recognized power supply is err−disabled.
4507#show power
Power Fan Inline
Supply Model No Type Status Sensor Status
PS1 PWR−C45−2800AC AC 2800W good good good
PS2 PWR−C45−1000AC AC 1000W err−disable good n.a.
!−−− Second recognized power supply is err−disabled.
*** Power Supplies of different type have been detected***
!−−− A mix of power supplies not supported.
Power Supply Max Min Max Min Absolute
(Nos in Watts) Inline Inline System System Maximum
PS1 1400 1400 1360 1360 2800
PS2 0 0 0 0 0
!−−− No power drawn from second power supply.
Power Summary
(in Watts) Available Used Remaining
System Power 1360 450 910
Inline Power 1400 18 1382
Maximum Power 2800 468 2332
Power supplies needed by system : 1
!−−− Switch configured for redundant mode.
Power Used Power Used
Mod Model (online) (in Reset)
1 WS−X4515 110 110
2 WS−X4515 110 110
Vista de pagina 17