Cisco IOSSoftware Configurationforthe Cisco12000Series One-PortChannelized OC-12/STM-4(DS1/E1)ISE Line
How to Configure Layer 1 Features
27
Cisco IOS Release 12.0(27)S1
Setting the Clock Source on a T1 Line
You can set the internal or line (network) clock source for a T1 line with the tug-2 tug-2-number
t1 t1-line-number clock source {internal | line} AU-3 configuration command. Table 6 describes the
syntax of this command.
Note On a T1 circuit, one end must provide the clock source by using the internal clock source.
The other end of the circuit can use either line or internal as the clock source.
The following example selects internal clocking for the first T1 line in the fourth TUG-2:
Router(config)# controller sonet 6/0
Router(config-controller)# au-3 1
Router(config-ctrlr-au3)# tug-2 4 t1 1 clock source internal
Router(config-ctrlr-au3)#
The following example selects line clocking for the first T1 line in the fourth TUG-2:
Router(config)# controller sonet 6/0
Router(config-controller)# au-3 1
Router(config-ctrlr-au3)# tug-2 4 t1 1 clock source line
Router(config-ctrlr-au3)#
Using the ping Command to Verify Network Connectivity
Following is an example of a successful ping command to a remote server with the address 10.0.0.10:
Router# ping 10.0.0.10
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echoes to 10.0.0.10, timeout is 2 seconds:
!!!!!
Success rate is 100 percent (5/5), round-trip min/avg/max = 1/15/64 ms
Router#
If the connection fails, verify that you have the correct IP address for the destination and that the device
is active (powered on), then repeat the ping command.
Proceed to the next section, “Using T1 Interface Loopback Modes,” to finish checking network
connectivity.
Table 6 T1 Line Clock Source Command Syntax
Range Description
tug-2 tug-2-number 1 to 7 When framing is SDH, AUG mapping is AU-3, and
mode of operation is c-11, tug-2-number is a number
in the range from 1 to 7.
t1 t1-line-number 1 to 4 In c-11 mode, a number in the range from 1 to 4.
clock source {internal |
line}
internal or line Defines the clock source for the T1 line. The default
clock source is internal.