Configuring Spectrum Management on an Upstream Cable Interface
Cisco uBR7200 Series MC16S Cable Modem Card Spectrum Management 25
cable upstream frequency
Enter a fixed frequency of the upstream RF carrier for an upstream port. You can also select a default
that does not set a specific fixed value. The valid range for a fixed upstream frequency is
5,000,000 Hz to 42,000,000 Hz (5 to 40 MHz). The Cisco uBR7200 series will command the
cable modems to use this frequency as the center frequency.
Note Some cable systems cannot reliably transport frequencies near these band edges. The wider
the upstream channel (in MHz), the more difficulty you could have. Enter a center frequency
between 20 and 38 MHz if you have difficulty.
cable upstream interface number frequency frequency
no cable upstream interface number frequency frequency
Syntax Description
Default
Dynamic (no fixed frequency)
Command Mode
Cable interface configuration
Command History
Example
See the following example to allow the Cisco uBR7200 series to dynamically specify a center
frequency upstream interface 0:
Router(config-if)# cable upstream 0 frequency
interface number Specifies the upstream interface on the cable modem card for
which you want to assign an upstream frequency.
frequency Specifies the center frequency (in Hz) for the given upstream
interface. Acceptable values range from 5000000 to 42000000. If
you wish to have the Cisco uBR7200 series dynamically specify a
center frequency for the given upstream interface, you can elect
not to enter any frequency value.
Release Modification
11.3 NA This command was introduced.