Chapter 1 Product Overview
Power Supplies
1-22
Catalyst 4500 Series Installation Guide
78-14409-03 B0
Catalyst 4500 series switches support one power supply and an optional
redundant power supply. Each power supply has an individual power cord and
status LEDs. Systems with redundant power supplies will share the load, with
each unit providing approximately one-half of the total load. For information
about configuring your switch for redundant and combined modes, refer to the
software configuration guide for your switch.
When power is removed from one power supply on a Catalyst 4500 series switch
that has two power supplies, the redundant power feature causes the second power
supply to produce full power.
To replace a power supply, see the “Removing and Replacing the Power Supply”
section on page 4-2.
Power Supply LEDs
Table 1-5 describes the power supply LEDs.
Table 1-5 Power Supply LEDs
LED Color/State Description
INPUT OK Indicates whether the input voltage is within the required range:
Green Input voltage is within the required range.
Flashing Input voltage is present, but is below required range.
Off Input voltage is below the required range or the power supply is
off.
OUTPUT FAIL Indicates whether the output voltage is within the specified
range:
Red Output voltage is not within the specified range.
Off Output voltage is within the specified range.
FAN OK Indicates the status of the power supply fans:
Green The fans are operational.
Off The fans are not operational.