Chapter 1 Product Overview
Power Supplies
1-24
Catalyst 4500 Series Installation Guide
78-14409-03 B0
Environmental Monitoring Feature
With the environmental monitoring and reporting feature, you can keep your
system running by resolving adverse environmental conditions before loss of
operation.
The power supply monitors its own internal temperature and voltages. In the event
of excessive internal temperature, the power supply shuts down to prevent
damage. When the power supply returns to a safe operating temperature, it
restarts. If the power supply output voltage is not within the specified range, the
LED labeled OUTPUT FAIL will light. An instance of substantial input
overvoltage can shut down the power supply.
An instance of substantial input overvoltage (greater than -75 VDC continuous)
can damage the power supply input circuitry and can cause it to shut down
permanently.
The main power switch has an input range of -40.5 to -72 VDC, while the -48 V
voice power switch operates over a range of -40.5 to -56 VDC. The voice power
will either fail to start or will shut down if exposed to greater than -56 VDC input.
Voice power will recover after you recycle input power within the proper voltage
range.
If the voice power shuts down due to input overvoltage (greater than -56 VDC),
the main convertor section will not shut down.
The supervisor engine monitors the status of each power supply and provides a
status report through the switch software. For more details on how the supervisor
engine monitors the power supplies, refer to the Catalyst 4000 Family Module
Installation Guide.