1-23
Catalyst 4500 Series Installation Guide
78-14409-03 B0
Chapter 1 Product Overview
Power Supplies
Power Supply Fan
Each power supply has a built-in fan. Air enters the front of the power supply
(power-input end) and exits through the back. An air dam keeps the airflow
separate from the rest of the chassis, which is cooled by the system fan assembly.
Load-Sharing Feature
When you install and turn on a second power supply on a Catalyst 4500 series
switch, it provides approximately one-half of the required power to the system. If
one power supply fails, the other power supply immediately assumes full power
to maintain uninterrupted system operation.
Note Load sharing works only when both power supplies in the chassis are the same
type.
When you install a redundant power supply, load sharing and fault tolerance are
enabled automatically; no additional software configuration is required.
In-line PWR (for
1400 W DC-input
power supplies
only)
Green Indicates the status of the in-line power connection:
-48 V passthru output voltage is enabled and is greater than
-39V and less then -60 V.
In-line PWR
(AC-input)
Off Indicates any of the following:
Passthru breakers are not enabled
DC input is less than -40.5 V
One or more -48V outputs is less then -39 V.
Amber Passthru breakers are enabled and input voltage exceeds -60 V.
Table 1-5 Power Supply LEDs (continued)
LED Color/State Description