11-11
Cisco Security Appliance Command Line Configuration Guide
OL-6721-01
Chapter 11 Configuring Failover
Understanding Failover
You can use the write standby command to resynchronize configurations that have become out of sync.
For Active/Active failover, the write standby command behaves as follows:
If you enter the write standby command in the system execution space, the system configuration
and the configurations for all of the security contexts on the security appliance is written to the peer
unit. This includes configuration information for security contexts that are in the standby state. You
must enter the command in the system execution space on the unit that has failover group 1 in the
active state.
If you enter the write standby command in a security context, only the configuration for the security
context is written to the peer unit. You must enter the command in the security context on the unit
where the security context appears in the active state.
Replicated commands are not saved to the Flash memory when replicated to the peer unit. They are
added to the running configuration. To save replicated commands to Flash memory on both units, use
the write memory or copy running-config startup-config command on the unit that you made the
changes on. The command will be replicated to the peer unit and cause the configuration to be saved to
Flash memory on the peer unit.
Failover Triggers
In Active/Active failover, failover can be triggered at the unit level if one of the following events occurs:
The unit has a hardware failure.
The unit has a power failure.
The unit has a software failure.
The no failover active or the failover active command is entered in the system execution space.
Failover is triggered at the failover group level when one of the following events occurs:
Too many monitored interfaces in the group fail.
The no failover active group group_id command is entered.
You configure the failover threshold for each failover group by specifying the number or percentage of
interfaces within the failover group that must fail before the group fails. Because a failover group can
contain multiple contexts, and each context can contain multiple interfaces, it is possible for all
interfaces in a single context to fail without causing the associated failover group to fail.
See the “Failover Health Monitoring” section on page 11-14 for more information about interface and
unit monitoring.
Failover Actions
In an Active/Active failover configuration, failover occurs on a failover group basis, not a system basis.
For example, if you designate both failover groups as active on the primary unit, and failover group 1
fails, then failover group 2 remains active on the primary unit while failover group 1 becomes active on
the secondary unit.
Note When configuring Active/Active failover, make sure that the combined traffic for both units is within the
capacity of each unit.