11-15
Cisco Security Appliance Command Line Configuration Guide
OL-6721-01
Chapter 11 Configuring Failover
Configuring Failover
When a unit does not receive hello messages on a monitored interface, it runs the following tests:
1. Link Up/Down test—A test of the interface status. If the Link Up/Down test indicates that the
interface is operational, then the security appliance performs network tests. The purpose of these
tests is to generate network traffic to determine which (if either) unit has failed. At the start of each
test, each unit clears its received packet count for its interfaces. At the conclusion of each test, each
unit looks to see if it has received any traffic. If it has, the interface is considered operational. If one
unit receives traffic for a test and the other unit does not, the unit that received no traffic is
considered failed. If neither unit has received traffic, then the next test is used.
2. Network Activity test—A received network activity test. The unit counts all received packets for up
to 5 seconds. If any packets are received at any time during this interval, the interface is considered
operational and testing stops. If no traffic is received, the ARP test begins.
3. ARP test—A reading of the unit ARP cache for the 2 most recently acquired entries. One at a time,
the unit sends ARP requests to these machines, attempting to stimulate network traffic. After each
request, the unit counts all received traffic for up to 5 seconds. If traffic is received, the interface is
considered operational. If no traffic is received, an ARP request is sent to the next machine. If at the
end of the list no traffic has been received, the ping test begins.
4. Broadcast Ping test—A ping test that consists of sending out a broadcast ping request. The unit then
counts all received packets for up to 5 seconds. If any packets are received at any time during this
interval, the interface is considered operational and testing stops.
If all network tests fail for an interface, but this interface on the other unit continues to successfully pass
traffic, then the interface is considered to be failed. If the threshold for failed interfaces is met, then a
failover occurs. If the other unit interface also fails all the network tests, then both interfaces go into the
“Unknown” state and do not count towards the failover limit.
An interface becomes operational again if it receives any traffic. A failed security appliance returns to
standby mode if the interface failure threshold is no longer met.
Note If a failed unit does not recover and you believe it should not be failed, you can reset the state by entering
the failover reset command. If the failover condition persists, however, the unit will fail again.
Configuring Failover
This section describes how to configure failover and includes the following topics:
• Configuring Active/Standby Failover, page 11-15
• Configuring Active/Active Failover, page 11-23
• Configuring Failover Communication Authentication/Encryption, page 11-32
• Verifying the Failover Configuration, page 11-32