
TN3270 Server Implementation 2-27
These commands can be specified in the TN3270 Server configuration mode the DLUR/Direct PU configuration
mode. The commands affect all the LUs under the PU based on the siftdown value.
The default value for the IP precedence screen and printer parameters is 0. If IP precedence is not configured, the
IP precedence field is set to 0 for both screen and printer. The default value for the IP ToS screen is 0.
When Telnet negotiation is taking place, IP precedence and IP ToS values of 0 are used. These values are used
until the Bind takes place. If it is a type 2 Bind, the TN3270 client is assumed to be screen. Otherwise, it is
assumed to be printer. These definitions of screen and printer might not be consistent with implementations in
other configurations or products. The IP precedence and IP ToS values are used until the TN3270 session is
terminated.
The show command displays four distinct values for IP precedence and the IP ToS. The values correspond to the
screen and printer. The following example shows the IP precedence and IP ToS as displayed in the show extended
command.
redback#show extended channel 3/2 tn3270-server
<current stats> <connection stats> <response time(ms)>
server-ip:tcp lu in-use connect disconn fail host tcp
172.28.1.99:23 0 0 1 1 0 0 20
total 0 0
configured max_lu 2100
idle-time 3600 keepalive 1800 unbind-action disconnect
ip-preced-screen 0 ip-preced-printer 0 ip-tos-screen 0 ip-tos-printer 0
tcp-port 23 generic-pool permit no timing-mark
dlur MPX.REDBCP status RESET
dlus MPX.NGMVMPC
name(index) ip:tcp xid state link destination r-lsap
PUS1(1) 172.28.1.99:23 05D19001 XID tok 0 4000.7470.00e7 08 A8
Configuring PU Parameters on the TN3270 Server
Configuring PU parameters is required when you configure PUs that do not use DLUR. To configure PU
parameters for the TN3270 Server, perform the following tasks (Table 2-8) beginning in TN3270 configuration
mode:
Table 2-8 PU Configuration Tasks
Task Command
Enter PU configuration mode and create or
delete PUs with direct host links.
pupu-name idblk-idnum ip-addresstype adapno
lsap [rmac rmac] [rsap rsap] [lu-seed
lu-name-stem]
(Optional) Assign a TCP port other than the
default of 23. This command is also available in
TN3270 configuration mode.
tcp-port port-nbr
(Optional) Specify the idle time for server
disconnect. This command is also available in
TN3270 configuration mode.
idle-time num-of-seconds
(Optional) Specify the maximum time allowed
between keepalive marks before the server
disconnects. This command is also available in
TN3270 configuration mode.
keepalive num-of-seconds
Comentarios a estos manuales