4 Module Mode Commands
80 4025561
Rev
A
show alarmparam
Syntax
show alarmparam alarmName alarmParamName
Description
The show alarmparam command is used to select a particular alarm (alarmName)
and display the value of a specified parameter for that alarm (alarmParamName).
Alarm parameters are settings that control when an alarm occurs, its severity, and
the size of the steps used to adjust alarm threshold settings.
Parameters
The alarmParamName parameter can have any of the following values:
alarmParamName Description
hysteresis Smallest unit of adjustment for alarm threshold.
majorhigh High threshold setting for a Major alarm.
majorlow Low threshold setting for a Major alarm.
minorhigh High threshold setting for a Minor alarm.
minorlow Low threshold setting for a Minor alarm.
The possible values for alarmName depend on the application module in question.
The following tables identify the alarms for each application module. For details on
alarm parameters and their possible values, see Module Parameter Descriptions (on
page
245).
Note:
When selecting parameters for this command, one or more wildcard characters
(*) may be used to specify a range of matching responses.
When entering this command, do not use the letter h to abbreviate hysteresis, as
this will instead invoke the help command.
Fan Tray (devtype: 5012)
alarmName Description
FansOK Fan operating status.
ChasTemp Chassis fan tray temperature.