Cha
te
4 Module Mode Commands
52 4025561
Rev
info alarm
Syntax
info alarm alarmName detail1 detail2 . . . detailn
Description
The info alarm command is used to display more detailed alarm information than is
returned by using the show command.
Parameters
The alarmName parameter specifies the type of alarm. The allowable alarmName
values vary by module because different modules have different types of alarms. To
learn about possible alarms for each module, do one of the following:
Use the modid command to select a single module (by chassis and slot location),
and then issue the command alarmstate * to list all available alarm names.
When entering this command, do not use the letter h to abbreviate hysteresis, as
this will instead invoke the help command.
See Module Parameter Descriptions (on page
245) for a list of possible alarms for
each module.
The detail parameters specify the characteristics that can be requested for each
alarmName, as follows:
Detail parameter Description
Hysteresis Threshold hysteresis value.
Index Alarm number, starting at 1, in the list of alarms.
Label Name of the alarm.
Limitadjust Allowed if alarm is adjustable, not allowed if not.
Majorhigh High Major threshold.
Majorlow Low Major threshold.
Minorhigh High Minor threshold.
Minorlow Low Minor threshold.
Nominal Alarm nominal value.
Rangehi Upper limit for this threshold.
Rangelo Lower limit for this threshold.