4 Module Mode Commands
88 4025561
Rev
A
show control
Syntax
show control controlName
Description
The show control command is used to display the values of all control parameters in
the range indicated by controlName.
Control Types
Control parameters are classified as type F (floating-point) or type S (state) to
characterize the types of variables they control. In general:
Type F controls are numeric values that can vary between maximum and
minimum thresholds. The adjustment increments are set by separate hysteresis
values for each control.
Type S controls are state variables that have a limited range of discrete values
such as On or Off, Master or Slave, Auto or Manual, and so on. The set of
possible values is defined as appropriate for each control.
Parameters
The values possible for the controlName parameter depend on the application
module in question. The following tables identify the controls for each application
module along with their types and possible values.
Note: When selecting control parameters for this command, one or more wildcard
characters (*) may be used to specify a range of matching responses.
Transmitter (devtype: 1033)
Control Description Type Possible Values
Enable Enables or disables the laser. S On (1), Off (0)
LenMode Fine tunes for length. S On (1) for Super Trunk links,
Off (0) for Edge Modulation
links
OMISet Sets the OMI level; only when
AGC ON.
F -6.0 dB to +1.0 dB in 0.5 dB
steps
CWMode CWMode ON reduces InRF
monitor value by 2 dB to indicate
actual modulation level.
S On (1), Off (0)