Step 2 Configure parameters for the voice interface.
a. Specify the PRI group and time slots to be mapped:
Gateway(config-controller)# pri-group timeslots 1-31 service mgcp
b. Configure each PRI group as a virtual serial interface:
Gateway(config-controller)# interface serial 1/0:15
c. Specify the E1 interface and unit number to modify:
interface Serial1/0:15
no ip address
no logging event link-status
isdn switch-type primary-net5
isdn incoming-voice voice
no cdp enable
Step 3 Configure the PRI port by entering the following command:
Gateway(controller-e1)# pri-group timeslots 1-31 service mgcp
Step 4 Bind Layer 3 to the Cisco CallManager for PRI Q.931:
Gateway(config-if)# isdn bind-l3 ccm-manager backhaul q931
This command backhauls (tunnels) ISDN Layer 3 and above to the
Cisco CallManager.
PRI/Q.931 signaling backhaul transports signals (Q.931 and higher layers) for
processing a PRI trunk that is physically connected to an MGCP call agent.
The ISDN lower layer information (Q.921 and below) is terminated and processed
on the gateway. The Layer 3 information (Q.923 and above) is transported over
TCP to the Cisco CallManager (MGCP call agent).
Step 5 Enable MGCP for the port by entering the following commands:
Gateway(config)# dial-peer voice 1 pots
Gateway(config-dial-peer)# application mgcpapp port
<portnumber>:<ds0group>
Replace portnumber with the port number on the voice gateway you are
configuring and ds0group with the DS0 group number.
Step 6 To view the status of the PRI line, enter the following command:
Gateway# show ccm-manager backhaul